PROCTORâ„¢ OVER FASCIA VENT 25mm x 1000mm #FV25 BAL

PROCTORâ„¢ OVER FASCIA VENT 25mm x 1000mm #FV25 BAL

PROCTORâ„¢ OVER FASCIA VENT 25mm x 1000mm #FV25 BAL

$23.95

Proctor over fascia vent FV25 BAL, 25mm x 1000mm, 25,000mm² airflow per metre for lower roof pitches and cathedral roofs. Pre-fitted BAL mesh for ember protection. All Orders placed before 10:00 am will be available for delivery next day or Pick-up within 1-2 days. You will receive a confirmation once your order will be ready for pick up. Orders placed over the weekend/public holiday will be processed on next working day. Any Question Give us a call on (03) 93941400 or email us on orders@singhroofingsupplies.com.au

SKU FV25BAL Category

SSL Protection

128 Bit SSL Certificate

Quick Shipping

Fast Shipping Australiawide

100% Satisfaction

We Put You First

The Full Kit

Proctor over fascia vent FV25 25mm x 1000mm
PROCTORâ„¢ OVER FASCIA VENT 25mm x 1000mm #FV25 BAL
$23.95
+
Proctor over fascia vent FV25 25mm x 1000mm
PROCTORâ„¢ OVER FASCIA VENT 25mm x 1000mm #FV25
$7.95
+
Proctor ridge vent RV10 2000mm
Proctor Ridge Vent 2000mm #RV10 BAL
$129.95
+
Proctor over fascia vent FV10 10mm x 1000mm
PROCTORâ„¢ OVER FASCIA VENT 10mm x 1000mm #FV10 BAL
$17.95

More Information

Proctor Over Fascia Vent FV25 BAL

The Proctor over fascia vent FV25 BAL is a 25mm x 1000mm eave vent with BAL mesh pre-fitted, made to draw air into the roof space between the sarking and the fascia board. It is the higher airflow version of the FV10, with a larger 25mm opening that pushes 25,000mm² of air per linear metre into the roof. The pre-fitted BAL mesh adds ember protection, which makes it the right pick where the build needs a bushfire-rated eave vent.

Key Features

  • 25,000mm² positive airflow per linear metre, 1/150 ratio
  • 1000mm length for a continuous eave run
  • Pre-fitted BAL mesh for ember protection
  • Reduced height profile, no need to pack out roof sheets
  • Increased rigidity and flutes make fixings easier to position
  • Suits timber and metal fascias

Specifications

  • Product: Proctor over fascia vent FV25 BAL
  • Size: 25mm x 1000mm
  • Airflow: 25,000mm² per linear metre, 1/150
  • Design: traditional roofs with pitch under 22 degrees, cathedral roofs of any pitch
  • Openings: 4mm, sized to block large insects and prevent capillary action
  • BAL: pre-fitted BAL mesh

Installation

The FV25 BAL fits between the fascia board and the roof cladding at the eave, with the openings facing into the roof space. Its reduced height keeps the vent discreet on the fascia line, and the flutes give a clean surface for the fixings so the vent stays put while the cladding goes on. Fit it before the roof sheets so the airflow path from the eave into the roof space is open from the start.

Applications

  • Eave ventilation on lower pitch roofs under 22 degrees
  • Cathedral roofs where a standard eave vent will not fit
  • Bushfire-prone areas where a BAL-rated vent is specified
  • New builds and re-roofing with a calculated ventilation system

What You Need To Complete The Job

The FV25 BAL is the inlet side of the ventilation system, so it needs an outlet at the ridge. Pair it with a Proctor ridge vent RV10 BAL for the same bushfire rating, or a standard Proctor RV10 where it is not required. See the Roof Ventilation range for the full system.

Frequently Asked Questions

When would I use the FV25 instead of the FV10?

The FV25 moves more air, 25,000mm² per linear metre against the FV10’s 10,000mm², and it is built for lower roof pitches under 22 degrees and cathedral roofs. The FV10 suits steeper traditional roofs over 16 degrees. Match the vent to the roof pitch and the ventilation calculation.

What does the BAL version add?

The BAL version has ember mesh pre-fitted, which stops embers and debris entering the roof space through the vent. It is the same 25mm x 1000mm body and airflow, just with the bushfire protection built in.

How does the vent let air in without letting water in?

The 4mm openings are sized so air passes freely but large insects cannot get in, and the openings are wide enough that capillary action cannot draw water up between them. The reduced height also keeps the vent low on the fascia, away from the water line.

Does it work on metal fascias?

Yes. The vent is compatible with timber and metal fascias, so it suits both traditional timber framed eaves and modern metal fascia lines.

Can I order for delivery or pickup?

Yes. You can order online and choose Australia-wide delivery or pickup from our Truganina trade counter in Melbourne’s west. Delivery windows depend on your postcode, and we send a confirmation once your order is ready. For any questions call (03) 93941400 or email orders@singhroofingsupplies.com.au.

Shopping cart0
There are no products in the cart!
Continue shopping
0

Get a Quote